SPECIFICATIONS
Building Area |
±1,000,000 SF |
Acres |
112.267 acres |
Ceiling Height |
40’ clear at first column line |
Column Spacing |
56’ wide x 48’ deep typical; 60’ deep speed bays |
Exterior Wall Construction |
Tilt-up panels |
Floor |
7” thickness, unreinforced, 4,000 psi concrete |
Drive-In Doors |
Four (4) automatic 14’ x 16’ doors |
Roof |
Fully-adhered 60 mil TPO system; 15 year warranty |
Dock Doors |
150 (9’ x 10’) manual OH steel doors. 32 additional knock-out panels |
Dock Equipment |
75 of the 150 dock doors are equipped w/ 45k lb mechanical pit-levelers, dock bumpers, dock seals and dock lights; electrical outlets are provided at every other door position |
Fire Protection |
ESFR sprinkler system with K-22.4 rated heads |
Electrical |
4,000 amp switchgear; 277/480 v3 phase |
Warehouse Lighting |
High-bay LED fixtures; 30 foot candles in speed bays and 1 fixture per structural bay in field of warehouse |
HVAC |
Roof mounted make-up air units; heated to 55 degrees interior at zero degrees at exterior |
Truck Courts |
130’ deep plus 55’ trailer storage row |
Car Parking |
437 auto stalls |
Trailer Parking |
237 trailer stalls. Expandable up to 289 stalls. |
Sewer |
8” line provided along each dock wall and down the center of the building in an “H” pattern. Olyphant Borough/Lackawanna River Basin Sewer Authority. |
Water |
3” Domestic Line & 10” Fire Line - PA American Water |
Gas |
High pressure line - UGI |